This four filter bichromatic calculating strip reader features a touch screen interface, on-board graphics printer, and a non-volatile memory to store over 50 user-defined tests. The standard model includes 4 filters, making it possible to load up to 3 strips at a time, and six-filter options are available. The onboard data reduction calculation includes regression to plot curve fitting and cut off absorbance calculation. This is made simple with step my step user prompting and the new larger screen display and graphical capabilities. It has a large- non-volatile memory to store over 100 user tests which can be transferred using parallel and serial outputs or printed via the optional onboard printer. The Strip Reader includes a carrier for break-apart strips up to 12 wells long. Optional carriers are available to accommodate non break-apart (rigid) 8-well or 12-well strips.

Stat Fax® 4700 Microwell Strip Reader

Options & Accessories

Linear Measurement Range:

0.0 to 3.0 Absorbance units (A)

Photometric Accuracy:

+/-(1% +/- 0.010) 0.0 through 1.5 Abs

+/-(2% +/- 0.010) 1.5 through 3.0 Abs

Stability:

Drift of no more than 0.005A in 8 hours/bichromatic

Light Source:

Tungsten lamp with lamp saver feature

Standard Wavelengths:

Standard: 405, 450, 492, and 630nm

6-VIS: 405, 450, 492, 545, and 630nm

6-UV: 340, 405, 450, 492, 545, and 630nm (alternate filters available from 240 to 700nm)

Filter Type

IAD hardcoat interference, 10nm half bandpass

Vessel:

Non-break-apart or break-apart strips up to 12 wells long, 3-strip loading capacity

Transport Mechanism

Automatic strip transport

Please reload

Technical Specifications
Software

Microstrip reader with bi-chromatic photometer system, works with both break-apart and non-break-apart strips

Easy to use with touch-screen display and built in printer

Selectable plate formatting will read trays containing microwell strips

Monochromatic or bichromatic reading

Uses standard microwell plates for all reactions

Open system

Four filter model (405 nm - 630 nm)

Optional 6 filter VIS model (405 nm - 630 nm)

Please reload

Photometric
Electronic
Other

Display:

Interactive touch-screen 3.5" LCD, color graphic display

Printer:

Thermal on-board printer with graphic capability

Power Requirements:

100V - 240V AC, 1.2A, 50-60Hz (universal input)

Interface:

USB mouse

Please reload

Speed:

Reads, calculates and prints results, 30 seconds per 12-well strip

Calculation Modes:

Single point calibration by standard or factor, multi-point calibration with point-to-point curve fit, -linear regressions with log, lin, and log-logit selections

Test Menu:

120 open channels to store tests

Stores all parameters including wavelengths, calculations, unit codes, ranges, interpretations, calibrator values, test names, and previous curve

Please reload

Enclosure:

Flame-retardant ABS plastic cover and base

Dimensions:

Approx. 9 x 13 x 5.5in (24 x 34 x 13cm), weighs 5 lbs. (4.5 kg)

Certifications:

NRTL listed, CE mark

Please reload