TKA 2 Microplate

Laboratories that perform few analyses can afford to equip themselves with one of these "walk-away" analyzers, thus avoiding the use of several machines. This helps in reducing costs, saving room, and protecting against human error. The programs allow the creation of profiles containing up to 8 assays to be carried out in a single session. It is also possible to carry out different assays on the same microplate, provided that such assays have the same temperature and incubation schedule. Like all TKA Analyzers the software of these units allow the storage of Standard Curves that can be retrieved later and used to adjust one or two calibrators, reducing analysis cost. Reagent containers are included in the kit.

TKA 2, 3, 6 and 8 Microplate Automated EIA Analyzers

Technical Specifications 

TKA 6 and 8 Microplate 

These are two top models of the new line and are particularly adequate to perform routine screening tests in laboratories having huge workloads and in blood banks, especially due to the use of eight needles. A whole microplate is processed in approximately 5 minutes (100 μl in individual quotas). Each incubator can freely programmed at an individual temperature. Futhermore, the instrument can be provided with the “STAT function" option that allows samples and new analysis, if so required, during the session.

2 Plates

Please reload

6 Plates

Please reload

Internally and externally coated in order to minimize the carry-over

8

1

Independent for each needle

10 pi

10-6 con sufficient needle washing

Option

8

8

12

Standard Washable Needles

Number of Needles

Liquid Level Sensor

Sample Minimum Volume

Pipetting Precision and Accuracy

Carry-Over of Washable Needles

Conductive Disposable Tips

Pump for Needle Washing

Maximum Number of Assays for Profile

Maximum Number of Microplates

Please reload

Number of Independent Incubators

Type

Closed and darkened

Temperature

It can be programmed from 2°C AT/ 50°C, at 0.1°C step

Temperature Accuracy

±2°C

Incubation Time

From 1 minute to 24 hours, to be programmed

Microplate Shaking

At intervals, to be programmed

Constant Microplate Shaking

Option

Please reload

Wavelength Range:

400/750nm (320/800nm on request)

Number of Standard Filters:

Standard Filters (nm):

Max. Number of Filter Positions:

Up to 6, automatically selected

Accuracy:

<1% at 450nm 1.0 OD

Linearity:

±1% at 450nm

Reproducability:

>±0.3% at 450nm, 1.0 OD (using neutral filter)

Range:

From 0 to 3 OD

Reading Speed:

< 5 seconds for single wavelength measurement

Kind of Reading:

Single/dual wavelength measurements

Please reload

There are no items in this list

Please reload

Manifold

8 distribution channels and 8 aspiration channels

Number of Washing Buffers

Dispensing Speed

To be programmed

Soak Time

To be programmed

Strip position

Automatic control of strip absence/presence

Please reload

850 Watts

750 Watts

650 Watts

600 Watts

110/230 V, 50/60 Hz

15ºC - 35ºC   (59ºF - 95ºF)

10% - 85% at 30ºC (85ºF) or below

1350 mm 

1670 mm 

2070 mm

1670 mm

790 mm

810 mm 

Hard disk, floppy, CD, keyboard, color monitor, and mouse included

RS 232 and parallel

Conductive disposable tips, bar code reader

Miscellaneous
Reader
Incubators
Washer
Configuration

TKA 3 Microplate

A high performance and profitability line, due to simultaneous action of 4 needles that distribute 96 samples in the microplate within a very short period. In order to avoid contamination each needle is fitted with its own membrane pump for internal washing purpose. The operator can freely choose up to a maximum of twelve assays to be included in the Profile to carry out. This unit is an adequate solution for medium-size laboratories.

3 Plates

Please reload

4

8 Plates

Please reload

1

Better than 1°/0 CV at 10°/0 syringe volume, based on gravimetric evaluation

1

1

4

8

12

2

3

6

8

3

3

4

4

2

3

6

8